Shandong Jingyao Glass: Ceramic Filter on 3 Kilns | ZTW Tech

Search intent: engineering reference|Shandong Jingyao Glass Group has three glass melting kilns running ceramic catalytic filter elements, and a fourth scope under construction. This article sets out what was installed, on what schedule, and what the reference data behind the claim actually is.

Project scope and commissioning schedule

Shandong Jingyao Glass Group Co., Ltd. operates several glass melting furnaces in Shandong province. Three of them are treated with ceramic catalytic filter elements under a combined desulphurisation, denitrification and dust removal scope, and the entries below are taken from the plant list published on this site.

  • No. 2 glass melting furnace — ceramic catalytic tube desulphurisation, denitrification and dust removal integrated project, in service since April 2024.
  • No. 1 glass melting furnace — same integrated scope, in service since October 2024.
  • No. 6 glass melting furnace — same integrated scope, under construction at the time of the plant list update.

The pattern is worth noting for anyone assessing a multi-line retrofit: the first line was commissioned in April 2024 and the second followed in October 2024, so the operating experience from the first line was available before the second was committed. The integrated ceramic flue gas treatment technology page describes the reactor arrangement behind this scope.

Treatment scope and the parameters that matter

Each line treats the flue gas from one glass melting furnace, so the duty is defined by the furnace rather than by a generic gas stream. Three parameter groups govern whether the scope works: the temperature window, the pore structure of the element, and the emission commitments that follow from the combination.

Parameter Value Duty condition
Element thermal rating up to 900 degC Ceramic fibre element, dry dust removal
deNOx operating window 220-400 degC Catalyst surface temperature
Peak efficiency band 280-400 degC Medium-temperature element series
Pore structure porosity over 80%, 24-45 nm Nano-porous ceramic fibre substrate
Dust commitment below 10 mg/Nm3 Clean gas side, particulate duty
deNOx commitment at or above 95% Inside the 220-400 degC window
deSOx commitment at or above 95% With dry sorbent dosing
Product rating 5-year warranty, 8-10 year maximum life Derated for high fluorine or sulfur duty

Two of those rows are often confused in tender documents. The 900 degC figure is the physical ceiling of the fibre element for dry dust removal; it is not a deNOx temperature. Quoting 900 degC against a denitrification duty is the single most common specification error, and it is the reason the deNOx window is stated separately.

The pore structure row carries a second consequence that procurement teams miss: because the same substrate carries the nano-catalyst, pore size and porosity do not only set dust collection and pressure drop, they also set how much catalyst can be impregnated and how quickly activity decays.

Operating record and how the reference data is used

On the Shandong Jingyao lines, the two commissioned furnaces have accumulated roughly two years of operating experience as of late 2026, and No. 6 was still under construction. The plant list records the operating model for these lines as owner-operated: the flue gas facilities are run by the owner's own staff, not by an external build-and-operate contractor.

Because per-line measured data at Jingyao is not published, the figures below come from a different but comparable installation using the same product family, and are quoted as a reference case rather than as Jingyao results: a 15,000 m3/h glass melting furnace treatment project in Sichuan, commissioned 2017-05-01 and accepted 2017-10-11. That project delivered NOx below 100 mg/m3 from an inlet above 3000 mg/m3, HF below 5 mg/m3 from above 38 mg/m3, SO2 below 5 mg/m3, particulate below 5 mg/m3 and ammonia escape below 5 ppm, with system differential pressure below 3500 Pa against above 4500 Pa for the equivalent conventional train on the same duty basis.

The referenced line used 416 ceramic filter elements in a four-chamber arrangement with 1306 m2 of total filtration area, at a total investment of 6 million CNY and combined operating cost of about 1.88 million CNY per year, with by-products returned to the glass batch so that no wastewater was generated.

Two things follow from this separation. First, a multi-line rollout is the normal way to test a ceramic system: let the first line establish the operating envelope and the maintenance pattern before committing the second. Second, the cost figures belong to that specific reference line and scale with gas volume and local labour rates, so they should be recalculated for a different furnace size rather than copied.

Frequently Asked Questions

Why install ceramic filter elements on several glass kilns at once?

Because the furnaces are operated on the same gas and the same product, the treatment duty repeats line by line, and the operating experience gained on the first line carries directly to the next. At Shandong Jingyao the second line entered service six months after the first, with the first line's data already available for design confirmation.

Does a ceramic filter element need a catalyst to work?

Only when denitrification is in scope. The same ceramic fibre substrate is used for both versions; the catalytic element adds a nano-catalyst impregnation. For dust and acid gas removal alone, or for duty above 400 degC where the catalyst would not survive, the plain fibre element is the correct choice.

How does the operating model affect maintenance planning?

On owner-operated lines, the owner holds the spare element stock and the regeneration procedure. That makes element changeover planning a scheduling question rather than a contractual one, and it is one reason to size the chamber count so that a single section can be isolated while the remaining sections keep running.

What should be measured at commissioning?

Outlet NOx, SO2, particulate and, where the furnace carries fluorine, HF — each recorded together with inlet concentration, oxygen content and flue gas temperature. The referenced Sichuan line also reported ammonia escape below 5 ppm, which matters as much as the pollutant concentrations themselves because excess ammonia carries a cost in reagent consumption and creates a secondary risk.

How long do the elements last on a glass furnace duty?

The product rating is a 5-year warranty with a maximum usable life of 8-10 years, but actual life follows operating hours and thermal cycling more closely than calendar age. The contract should state which baseline binds: commissioning date, first operating date, or accumulated operating hours.

Technical basis and further reading

ZTW's ceramic catalytic tube multi-pollutant coordinated control technology is listed in the 2018 National Catalogue of Advanced Pollution Prevention and Control Technologies issued by the Ministry of Environmental Protection (Announcement No. 76 of 2018), and the ceramic catalytic integrated flue gas multi-pollutant coordinated control technology in the 2020 National Catalogue of Major Environmental Protection Technologies and Equipment Encouraged for Development issued by the Ministry of Industry and Information Technology with the Ministry of Science and Technology and the Ministry of Environmental Protection.

Related reading




ZTW
We will reach you within 1 hour.
2026-11-25 07:39:52
Hello, welcome to ZTW. Please reach out to us at any time.
We have received your ticket and will get back to you within 24 hours.
Cancel

Select the chat tool: